Fiber Optic Cables · 24FMTPSMF
Customized Length MTP® Breakout Cable, MTP®-24 APC (Female) to 2 x MTP®-12 APC (Female), 24 Fibers, Single Mode (OS2), Plenum (OFNP), 0.35dB Max, Type A
Customized Length MTP® Breakout Cable, MTP®-24 APC (Female) to 2 x MTP®-12 APC (Female), 24 Fibers, Single Mode (OS2), Plenum (OFNP), 0.35dB Max, Type A, Yellow, Product Specification:Fiber Connector - US Conec MTP®, Gender - Female, Fiber Mode - OS2 9/125μm, Wavelength - 1310/1550nm, Glass Fiber - G.657.A1, Polish Type - APC to APC
Net price · DE
€175,00
ex. VAT
In stock
1-year warranty · Netcore-backed
MTP® Breakout Cable, MTP®-24 F APC to 2 x MTP®-12 F APC, 24F, OS2, OFNP, Type A
MTP® Breakout cable is designed to provide a more flexible multi-fibre cabling system based on MTP® products. Unlike MTP® harness cable, MTP® Breakout cables are terminated with MTP® connectors on both ends and can provide more possibilities for the existing 24-fibre cabling system.
The 40/100G MTP® Breakout cables eliminate the wasted fibres in current 40G transmission and upcoming 100G transmission. Compared to purchase and install separate Breakout cassettes, using MTP® Breakout cables is a more cost-effective and lower-loss option.
Highlights
- 01US Conec MTP® Connector with Optimal 0.35dB Low IL
- 02G.657.A1 Bend Insensitive Fiber with 10mm Min. Bend Radius
- 03OFNP Fire Safety-Rated for Use in Plenum Air Spaces
- 04Color-Coded Connector Boots for Easy Identification
- 05Convert from 24 to 12 Fibers for 100% Fiber Utilizations
- 06Compliant to IEC 61754-7, ANSI/TIA-604-5 and ANSI/TIA-568.3-D
Specifications
18 fields| Fiber Connector | US Conec MTP® |
| Gender | Female |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Glass Fiber | G.657.A1 |
| Polish Type | APC to APC |
| Insertion Loss | ≤0.35dB (0.15dB Typ.) |
| Return Loss | ≥60dB |
| Attenuation at 1310nm | ≤0.35dB/km |
| Attenuation at 1550nm | ≤0.21dB/km |
| Cable Jacket | Plenum (OFNP) |
| Minimum Bend Radius | 10mm |
| Cable Outside Diametre (OD) | 3.0mm |
| Breakout Length | 0.5m |
| Installation Tensile Load | 66N |
| Tensile Strength | 80/240N (Long/Short Term) |
| Operating Temperature | -10 to 60°C (14 to 140℉) |
| Storage Temperature | -10 to 70°C (14 to 158℉) |
Features
Plenum Jacket, The Highest Fire Safety-Rated
High Density Cabling for Various Environments
It provides conversion from 24 to 12 Fibers connectivity for 100% Utilization of fibres.
- Data Centers
- Storage Area Networks (SAN)
- Communications Rooms