netcore
Sign in
6in (0.15m) Cat6a 26AWG Snagless Shielded (S/FTP) PVC CM Ethernet Network Patch Cable, Blue, 24Pcs/pack
1 / 8
Copper Systems · C6ASFTPSGPVC-24PK

6in (0.15m) Cat6a 26AWG Snagless Shielded (S/FTP) PVC CM Ethernet Network Patch Cable, Blue, 24Pcs/pack

6in (0.15m) Cat6a 26AWG Snagless Shielded (S/FTP) PVC CM Ethernet Network Patch Cable, Blue, 24Pcs/pack, Product Specification:Cable Type - Cat6a Snagless, Shielding Type - Shielded (S/FTP), Cable Jacket - PVC CM (Round), Length - 6in (0.15m) (Including Plugs), Conductor Material - >99.95% Oxygen-free Copper, Conductor Type - Stranded

Net price · DE
€41,00
ex. VAT
In stock
1-year warranty · Netcore-backed

Cat6a Snagless Shielded (S/FTP) Ethernet Network Patch Cable, 26AWG, 10GBase-T

Cat6a network patch cable is a cost-effective solution for indoor data centre applications, supporting up to 10GBase-T and 550MHz over 100 metres while remaining fully backward compatible with previous categories. Built with high-conductivity pure bare copper, it minimises signal attenuation for reliable performance. The shielded design delivers strong alien crosstalk suppression and protects critical data from EMI/RFI interference. Its eco-friendly PVC CM jacket is durable, flame-retardant, and bend-resistant, while the stranded copper construction offers longer flex life. Tested to meet ANSI/TIA-568.2-D and ISO/IEC 11801 standards, it also supports PoE for easier device deployment in locations far from power outlets. With eight-core, four-pair precision twisting and Fluke-tested performance, it ensures stable, accurate, and high-speed data transmission.

Highlights

Specifications

18 fields
Cable TypeCat6a Snagless
Shielding TypeShielded (S/FTP)
Cable JacketPVC CM (Round)
Length6in (0.15m) (Including Plugs)
Conductor Material>99.95% Oxygen-free Copper
Conductor TypeStranded
Data Rate Support10GBase-T
Maximum (Tested) Frequency550MHz
Gauge (AWG)26 (7/0.16mm)
Cable Outer Diametre (mm)6.2 ± 0.3
Max Transmission Distance100m
Twisted Pairs4 Pairs
Wire SchemeT568B, Straight
StandardISO/IEC 11801, ANSI/TIA-568.2-D 
Plug Type8 Position
Support FSWireNetNo
Operating Temperature-20 to +75°C (-4 to 167°F)
Installation Temperature-10 to +50°C (14 to 122°F)

Features

550MHz Stable Transmission

This cable speeds up to 550MHz and supports 10GBase-T Ethernet, which allows for more reliable data transmission.

  • 24K 50μ'' Gold-plated Connectors
    Stable Transmission
  • >99.95% Oxygen-free Copper Conductors
    Less Signal Loss
  • Stranded 4 Twisted Pairs
    Anti-electromagnetic Interference

Triple Protection of Patch Cables

Copper Cabling Solutions for Data Center

  • Provide cost-effective copper cable solutions for major corporations, medium-sized and small enterprises data centres.

Fluke Networks-Channel Testing

Visual Cable Management with Free FSWireNet

Datasheets & documents