Fiber Optic Cables · ID-SMXX4F
Customized 4 Fibers OS2 Single Mode LC/SC/FC/ST/LSH Indoor Tight-Buffered Multi-Fiber Breakout Cable
Buy 4 Fibres single mode indoor multi-fibre pre-terminated fibre optic cable, PVC jacket, from reliable fibre optic cable supplier - FS.COM.
Net price · DE
€12,00
ex. VAT
In stock
1-year warranty · Netcore-backed
4 Fibers 9/125 Single Mode Indoor Multi-Fiber Pre-Terminated Breakout Cable
Indoor multi-fibre breakout cable is a low-cost cable designed primarily for indoor interconnection between transmission equipment and patch panels or similar fixed routes. Designed with carrier-grade quality, this cable features superior assemblies that minimise light loss during bending for reliable transmission in tight spaces. The fibre optic cable has industry standard flammability rating jacket and the connector meets EIA/TIA 604-2 for high speed cabling networks.
Highlights
- 01Available in LC/SC/FC/ST/LSH Connector
- 02Available in Riser (OFNR)/LSZH/Plenum (OFNP) Flame-Retardant Jacket
- 03Available in Four Different Breakout Types
- 04Available in 2.0/0.9mm Breakout Diametre
- 05Available in Pulling Eye to Prevent the Cables from Twisting During the Installation Process
- 06Optical Performance Test for Normal Network Connections
- 07Used for Indoor Interconnection in Data Center Applications
Specifications
18 fields| Connector Type | LC/SC/ST/FC/LSH |
| Polish Type | UPC/APC |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Fiber Count | 4 Fibers |
| Cable Jacket | Riser (OFNR)/LSZH/Plenum (OFNP) |
| Fiber Grade | G.657.A1 |
| Minimum Bend Radius | 20/10D (Dynamic/Static) |
| Insertion Loss | ≤0.3dB |
| Return Loss | UPC≥50dB, APC≥60dB (LC/SC/ST/FC)<br/>UPC≥50dB, APC≥65dB (LSH) |
| Attenuation at 1310nm | 0.36dB/km |
| Attenuation at 1550nm | 0.22dB/km |
| Breakout Outside Diametre (OD) | 2.0/0.9mm |
| Trunk Outside Diametre (OD) | 7.5±0.5/4.8±0.3mm |
| Breakout Type | 0.3/0.5m Equal Breakout (Default) |
| Polarity (Duplex) | A (Tx) to B (Rx) |
| Operating Temperature | -10 to 60°C (14 to 140℉) |
| Storage Temperature | Riser (OFNR)/Plenum (OFNP): -20 to 70°C (-4 to 158°F) <br/>LSZH: -40 to 70°C (-40 to 158℉) |
Features
Two Polish Types for Various Signal Sensitivity Demands
The fibre endface of APC is polished at an 8° angle and UPC is polished with no angle. Please note <br>that the two connectors cannot be mated or they will be unusable.
Three Jacket Materials Used in Diverse Cabling Zone
Breakout Types for Optimizing Cable Routing
Two Cable Diametres for Different Wiring Needs
The slim and robust indoor multi-fibre patch cable is not only cabling in high-density data centres<br>but also terminated into rack mount and wall mount enclosures.