7.20kW Single-Phase 30A/240V Switched Rack PDU, 21 x C13 & 3 x C19 Outlets, NEMA L6-30P Plug, 10ft Cord, 0U Vertical
1 / 9
Networking · PDU-L6324I-VSW

7.20kW Single-Phase 30A/240V Switched Rack PDU, 21 x C13 & 3 x C19 Outlets, NEMA L6-30P Plug, 10ft Cord, 0U Vertical

7.20kW Single-Phase 30A/240V Switched Rack PDU, 21 x C13 & 3 x C19 Outlets, NEMA L6-30P Plug, 10ft Cord, 0U Vertical, Product Specification:PDU Type - Switched, Phase - Single-phase, Input Plug Type - NEMA L6-30P, Output Socket Type - 21 C13 & 3 C19, Input Voltage - 100-240V, Output Voltage - 100-240V

Net price · DE
€1.043,00
ex. VAT
In stock
2-year warranty · Netcore-backed

7.20kW Single-Phase 30A/240V Switched Rack PDU, 21 x C13 & 3 x C19 Outlets, NEMA L6-30P Plug, 10ft Cord, 0U Vertical

The switched rack PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. A digital ammetre allows you to monitor each phase's current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The built-in network interface enables full remote access for PDU status monitoring and email notifications via Web and Zabbix. Protocols supported include Telnet, HTTP/HTTPS, SNMPv1/v2c/v3, NTP, SNTP, SMTP, TCP/IP, UDP, DHCP, 10Base‑T/100Base‑TX, Ping, Modbus TCP. The switched rack PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets.

Highlights

Specifications

26 fields
PDU TypeSwitched
PhaseSingle-phase
Input Plug TypeNEMA L6-30P
Output Socket Type21 C13 & 3 C19
Input Voltage100-240V
Output Voltage100-240V
Input Current Limits30A
Rating Current30A
Load Capacity7.20kW
Frequency Compatibility50/60Hz
Cord Length10ft (3m)
Cord Gauge10AWG
AmmetreLCD Hot Swapping
Circuit Breaker1, Magnetic-hydraulic
Front Panel LCD DisplayDigital metre reports PDU output current in amps, voltage, capacity, electric energy, temperature and humidity, and IP address information
Network Compatibility10/100Base-T
SNMP CompatibilitySupporting Web, Telnet, HTTP/HTTPS, SNMPv1/v2c/v3, NTP, SNTP, SMTP, TCP/IP, UDP, DHCP, 10Base‑T/100Base‑TX, Ping, Modbus TCP and Zabbix software for local and remote management
Mounting PositionVertical
Rack Units0U
Minimum Required Rack Height42U
Dimensions (HxWxD)67.24"x2.36"x3.15" (1708x60x80mm)
Toolless Mounting PegUnmovable
Rack Mount BracketsRemovable
Storage Temperature-20 to 60°C (-4 to 140°F)
Operating Temperature0 to 50°C (32 to 122°F)
Relative Humidity0~80%, Non-condensing

Features

Local Power Monitoring and Hardware-Level Protection

A hot-swappable ammetre provides real-time power visibility, while circuit breaker protection and an industrial-grade plug ensure reliable local power control and long-term safety.

  • Hot-swappable ammetre reports PDU input current, voltage, capacity, electric energy, temperature and humidity, buzzer switch state, and IP address information.
  • The 30A magnetic-hydraulic circuit breaker identifies faulty power supplies and trips automatically to prevent overload.
  • Locking input plug protects critical equipment by maintaining a secure link without failure.

Integrated Ports for Power, Monitoring, and Expansion

Locking Outlet Design for Stable Connection

Remote Monitoring for Centralized and Proactive Management

Redundant Power Minimizes the Risk of Downtime

Cascade up to 128 PDUs to Simplify and Speed Deployment

Easy 0U Installation in EIA-Standard 19" Racks

The PDU features tool-free installation and versatile mounting options, allowing vertical placement on the side or rear of the rack to optimise space and airflow in 42U and larger racks.

Multi-Scene Application

Recommended for data centres, server rooms and network closets. You can more efficiently manage network power consumption and properly balance loads without having to visit the site. Reducing the number of on-site visits can help lower the cost of data centre maintenance.

  • Data Centers
    Distribute clean AC power from an uninterruptible power supply (UPS), generator, or utility power source throughout entyre data centres to keep essential equipment running at peak performance.
  • Server Rooms
    Play a crucial role in server rooms by providing remote power management, facilitating troubleshooting, enabling energy efficiency management, and ensuring load balancing.
  • Network Closets
    Ensure you are delivering reliable power to network closets and equipment from a variety of power sources, such as uninterruptible power supply (UPS), generators, or utility power sources.