6.24kW Single-Phase 30A/208V Switched Rack PDU, 21 x C13 & 3 x C19 Outlets, NEMA L6-30P Plug, 10ft Cord, 0U Vertical
1 / 10
Networking · PDU-L6324I-VSW

6.24kW Single-Phase 30A/208V Switched Rack PDU, 21 x C13 & 3 x C19 Outlets, NEMA L6-30P Plug, 10ft Cord, 0U Vertical

30A/208VIndividual Outlet Control

FS 6.24kW Single-Phase Switched Vertical PDU Power Strip delivers benifits of individual outlet control, remote management, monitoring of PDU vitals and networked clients as well as locally monitor load level.

Net price · DE
€1.233,00
ex. VAT
In stock
2-year warranty · Netcore-backed

6.24kW Single-Phase 30A/208V Switched Rack PDU, 21 C13 & 3 C19 Outlets, NEMA L6-30P Plug, 10ft Cord, 0U Vertical

Switched PDU can locally monitor load level and avoid potential overloads with an LCD hot swapping display, as well as remotely control individual outlets for the rebooting of locked equipment to avoid costly service calls, custom power-on/power-off sequences, and load-shedding of non-essential loads during blackouts to extend battery backup runtime for critical equipment. Optional T/H sensor to set notification forms to prevent business disruption.
The PDU network interface connects to an Ethernet jack. Remote users can switch each of the PDU outlets on or off via SNMP and the Web. Remote outlet level control allows on/off power cycling to remotely restart equipment and limits unauthorised use of individual outlets to reduce downtime.
1 IP is required to access up to 32 PDUs in a single cascade group. Outlet power sequencing and grouping allow the user to specify the device power-on or power-down sequence to avoid overloading the circuit due to inrush current or load reduction to drive green data centre initiatives to save energy and money.
The 0U rack PDU mounts vertically using the included toolless mounting buttons or the included brackets. Recommended for data centres, server rooms, and network closets, this 0U vertical PDU provides advanced network control and remote power monitoring.

Highlights

Specifications

28 fields
PDU TypeSwitched
PhaseSingle-phase
Input Plug TypeNEMA L6-30P
Output Socket Type21 C13 & 3 C19
Input Voltage208V<br/>
Output Voltage208V
Input Current Limits30A
Rating Current30A
Load Capacity6.24kW
Frequency Compatibility50/60Hz
Cord Length10ft (3m)
Cord Gauge10AWG
AmmetreLCD Hot Swapping
Circuit Breaker2, Magnetic-hydraulic
Front Panel LCD DisplayDigital metre reports PDU output current in amps, voltage, capacity, electric energy, temperature and humidity, and IP address information
Network Compatibility10/100Base-T
SNMP CompatibilitySupporting Web, Telnet, SSL, SNMPv1/v2c/v3, NTP, SMTP for local and remote management
Material of ConstructionMetal Plate
Mounting PositionVertical
Rack Units0U
Minimum Required Rack Height42U
Dimensions (HxWxD)72.05"x2.2"x2.01" (1830x56x52mm)
Toolless Mounting PegUnmovable
Rack Mount BracketsRemovable
Storage Temperature-15°C~60°C (5°F ~ 140°F)
IEC Receptacle LockingYes
Operating Temperature0°C~55°C (32°F ~ 131°F)
Relative Humidity10~95%, Non-condensing

Features

Simple to Deploy, Simple to Use

Switched PDU Application

Advanced Network Control And Remote Power Monitoring

  • User-defined Alarm Thresholds
  • LCD Screen Local Monitoring
  • Individual Outlet Control
  • Optional T/H Sensor

Redundant Power Minimizes the Risk of Downtime

The Excellent Workmanship of Monitored PDU

Serial Bus Cascade 32 Units PDUs

Access, Configure, and Control through MPDU Software

  • Monitoring and Control
  • Operation Log Record
  • Visual interface

Easy 0U Installation in EIA-Standard 19 in Racks

The PDU features tool-free installation and versatile mounting options, allowing vertical placement on the side or rear of the rack to optimise space and airflow in 42U and larger racks.

Multi-Scene Application

Recommended for data centres, server rooms and network closets. You can more efficiently manage network power consumption and properly balance loads without having to visit the site. Reducing the number of on-site visits can help lower the cost of data centre maintenance.

  • Data Centers
    Distribute clean AC power from an uninterruptible power supply (UPS), generator, or utility power source throughout entyre data centres to keep essential equipment running at peak performance.
  • Server Rooms
    Play a crucial role in server rooms by providing remote power management, facilitating troubleshooting, enabling energy efficiency management, and ensuring load balancing.
  • Network Closets
    Ensure you are delivering reliable power to network closets and equipment from a variety of power sources, such as uninterruptible power supply (UPS), generators, or utility power sources.